60BCh, 68BCh Touch probe 2 position positive value - Axis #
The position latched on the rising edge
A rising edge is the transition of a digital signal from low to high. It is also called positive edge of the touch probe 2 input.
See Touch Probes.
Axis 1
| Parameter | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable |
|---|---|---|---|---|---|---|---|
| Touch probe 2 position positive value - Axis 1 | 60BCh | 0h | Signed32 | - | Position | Read only | Yes |
Axis 2
| Parameter | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable |
|---|---|---|---|---|---|---|---|
| Touch probe 2 position positive value - Axis 2 | 68BCh | 0h | Signed32 | - | Position | Read only | Yes |